Mostrar el registro sencillo del ítem

Absolute quantification of human serum transferrin by species-specific isotope dilution laser ablation ICP-MS

dc.contributor.authorKonz Gherghel, Ioana 
dc.contributor.authorFernández García, Beatriz 
dc.contributor.authorFernández Sánchez, María Luisa 
dc.contributor.authorPereiro García, María Rosario 
dc.contributor.authorSanz Medel, Alfredo 
dc.date.accessioned2013-01-30T10:22:13Z
dc.date.available2013-01-30T10:22:13Z
dc.date.issued2011
dc.identifier.citationAnalytical Chemistry, 83(13), p. 5353-5360 (2011); doi:10.1021/ac200780bspa
dc.identifier.issn0003-2700
dc.identifier.urihttp://hdl.handle.net/10651/11042
dc.description.abstractWe report for the first time the absolute quantification of a metalloprotein separated by nondenaturing gel electrophoresis (GE) using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) in combination with species-specific isotope dilution mass spectrometry (IDMS). The proposed method is based on the use of an isotopically enriched 57Fe-transferrin complex to quantify natural transferrin (Tf) in human serum samples. First, the saturation process of Tf with natural abundance or isotopically enriched 57Fe was accomplished by using freshly synthesized Fe-citrate solutions. The stability of the metal-protein complex as well as its stoichiometry was investigated by spectrophotometry and ICP-MS, demonstrating a satisfactory stability over a period of at least one month and a molar ratio Fe:Tf of 1.94 ± 0.09, which is close to the expected value of 2. The species-specific IDMS method was compared with external calibration using the Fe-Tf (absolute Tf amount between 2 and 10 μg) and different sample preparation procedures (stained and nonstained gels) as well as two laser ablation strategies (single line ablation in the direction perpendicular or horizontal to the electrophoretic migration) were evaluated. The proposed species-specific GE-LA-ICP-IDMS method was tested for the analysis of a serum certified reference material (ERM-DA470k/IFCC). The results were in good agreement with the certified value with relative standard deviation values in the range of 0.9–2.7% depending on the data treatment procedure used. Furthermore, the analysis time has been drastically reduced in comparison with previous approaches to less than 15 min. The quantification by species-specific GE-LA-ICP-IDMS allowed us to obtain accurate and precise results not only by analyzing the protein spot in the middle position but also in the adjacent ablation line to the center.spa
dc.format.extentp. 5353-5360spa
dc.language.isoeng
dc.relation.ispartofAnalytical Chemistryspa
dc.rights(c) American Chemical Society
dc.sourceWOKspa
dc.titleAbsolute quantification of human serum transferrin by species-specific isotope dilution laser ablation ICP-MSspa
dc.typejournal article
dc.identifier.local20111339spa
dc.identifier.doi10.1021/ac200780b
dc.relation.publisherversionhttp://dx.doi.org/10.1021/ac200780bspa


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem